<p>The principle of operation: The FLS displays the current fuel level in conventional units (in the range from 30 to 4095 by default). Then, using the calibration table of this capacity and the "automatic calibration" option of the Mielta DM application, the data is converted into liters.</p>
<p>Taring does not forgive gross mistakes and requires strict compliance with the regulations: The FLS is installed on an empty tank. The tank is filled with fuel in equal measured portions (“taring step”) to the neck. It is recommended to top up at least 20 equal portions per tank. After each step, the tank filling level is fixed. The obtained indicators are summarized in a calibration table.</p>
<p>Any other questions? Mielta Technology technical support specialists are ready to help with calibration of the tank for Mielta by phone: +78005506878.</p>
Measure it seven times, pour it once. Taring of the fuel level sensor.
The accuracy of the FLS readings directly depends on the setup and preparation of the equipment for operation. To “introduce” the sensor to the new tank is the task of taring.
|